{"id":3925,"date":"2016-02-03T21:45:50","date_gmt":"2016-02-03T21:45:50","guid":{"rendered":"https:\/\/alt2.minisoft.com\/support\/?p=3925"},"modified":"2020-06-25T12:14:52","modified_gmt":"2020-06-25T19:14:52","slug":"adding-a-remote-iseries-queue-to-a-toolkit-configuration-file","status":"publish","type":"post","link":"https:\/\/www.minisoft.com\/support\/adding-a-remote-iseries-queue-to-a-toolkit-configuration-file\/","title":{"rendered":"Adding a Remote iSeries Queue to a toolkit configuration file"},"content":{"rendered":"<p>You can access spool files on remote iSeries systems from any systems, including iSeries, Unix, and Windows, by using the Remote iSeries Queue option of the eFORMz Director Toolkit.<\/p>\n<p><strong>Prerequisite:<\/strong> You must first complete the configuration procedure in <a href=\"\/support\/index.php\/director-setup-for-unix\/#DirectorConfig\">Director Setup<\/a>.<\/p>\n<p><strong>Adding\u00a0a Remote iSeries Queue<\/strong><\/p>\n<ol>\n<li>Open an existing toolkit configuration file or creating a new file.<\/li>\n<li>Right click the file name &gt; Add Input &gt; Remote iSeries queue.\u00a0Alternatively, you can click the configuration file name and click Add &gt; Remote iSeries queue.<a href=\"https:\/\/alt2.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq5.jpg\" rel=\"attachment wp-att-3930\"><img decoding=\"async\" loading=\"lazy\" class=\"size-medium wp-image-3930 aligncenter\" src=\"https:\/\/alt2.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq5-300x289.jpg\" alt=\"riq5\" width=\"300\" height=\"289\" srcset=\"https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq5-300x289.jpg 300w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq5-150x145.jpg 150w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq5-250x241.jpg 250w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq5-550x530.jpg 550w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq5-187x180.jpg 187w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq5-311x300.jpg 311w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq5-518x500.jpg 518w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq5.jpg 617w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/li>\n<li>Type a name for the queue. This name is used in Director utilities and the log files.<\/li>\n<li>Type the host name or IP address of the target system.<\/li>\n<li>Type\u00a0the user ID and password of an identity permitted to access the OUTQs and spool files of the target system.<a href=\"https:\/\/alt2.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq2.jpg\" rel=\"attachment wp-att-3927\"><img decoding=\"async\" loading=\"lazy\" class=\"size-medium wp-image-3927 aligncenter\" src=\"https:\/\/alt2.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq2-300x241.jpg\" alt=\"riq2\" width=\"300\" height=\"241\" srcset=\"https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq2-300x241.jpg 300w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq2-150x120.jpg 150w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq2-250x200.jpg 250w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq2-224x180.jpg 224w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq2-374x300.jpg 374w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq2.jpg 540w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/li>\n<li>Put the curor in the Password field and press Tab twice to start a connection to the remote system. The Input Queue list box is\u00a0populated with the values found.<a href=\"https:\/\/alt2.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq3.jpg\" rel=\"attachment wp-att-3928\"><img decoding=\"async\" loading=\"lazy\" class=\"size-medium wp-image-3928 aligncenter\" src=\"https:\/\/alt2.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq3-300x243.jpg\" alt=\"riq3\" width=\"300\" height=\"243\" srcset=\"https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq3-300x243.jpg 300w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq3-150x121.jpg 150w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq3-250x202.jpg 250w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq3-222x180.jpg 222w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq3-371x300.jpg 371w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq3.jpg 536w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/li>\n<li>Select an input queue.\u00a0Additional options can be selected. These options are covered in the\u00a0<a href=\"\/support\/index.php\/director-setup-for-unix\/#DirectorConfig\">Director Setup<\/a>\u00a0page.<\/li>\n<li>Click OK to\u00a0add one or more file selectors.<img decoding=\"async\" loading=\"lazy\" class=\"size-medium wp-image-3932 aligncenter\" src=\"https:\/\/alt2.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq7-300x121.jpg\" alt=\"riq7\" width=\"300\" height=\"121\" srcset=\"https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq7-300x121.jpg 300w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq7-150x60.jpg 150w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq7-250x101.jpg 250w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq7-550x222.jpg 550w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq7-447x180.jpg 447w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq7.jpg 613w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/li>\n<li>The File list will be populated with the names of spool files that currently exist in the queue for your convenience.\u00a0Ensure the proper Format is selected for the type of file.<a href=\"https:\/\/alt2.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq4.jpg\" rel=\"attachment wp-att-3929\"><img decoding=\"async\" loading=\"lazy\" class=\"size-medium wp-image-3929 aligncenter\" src=\"https:\/\/alt2.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq4-300x264.jpg\" alt=\"riq4\" width=\"300\" height=\"264\" srcset=\"https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq4-300x264.jpg 300w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq4-150x132.jpg 150w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq4-250x220.jpg 250w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq4-204x180.jpg 204w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq4-341x300.jpg 341w, https:\/\/www.minisoft.com\/support\/wp-content\/uploads\/2016\/02\/riq4.jpg 493w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/li>\n<li>You can select additional options. These options are covered in <a href=\"\/support\/index.php\/director-setup-for-unix\/#DirectorConfig\">Director Setup<\/a>.<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>You can access spool files on remote iSeries systems from any systems, including iSeries, Unix, and Windows, by using the Remote iSeries Queue option of the eFORMz Director Toolkit. Prerequisite: You must first complete the configuration procedure in Director Setup. Adding\u00a0a Remote iSeries Queue Open an existing toolkit configuration file or creating a new file. [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"_links":{"self":[{"href":"https:\/\/www.minisoft.com\/support\/wp-json\/wp\/v2\/posts\/3925"}],"collection":[{"href":"https:\/\/www.minisoft.com\/support\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.minisoft.com\/support\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.minisoft.com\/support\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.minisoft.com\/support\/wp-json\/wp\/v2\/comments?post=3925"}],"version-history":[{"count":5,"href":"https:\/\/www.minisoft.com\/support\/wp-json\/wp\/v2\/posts\/3925\/revisions"}],"predecessor-version":[{"id":8110,"href":"https:\/\/www.minisoft.com\/support\/wp-json\/wp\/v2\/posts\/3925\/revisions\/8110"}],"wp:attachment":[{"href":"https:\/\/www.minisoft.com\/support\/wp-json\/wp\/v2\/media?parent=3925"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.minisoft.com\/support\/wp-json\/wp\/v2\/categories?post=3925"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.minisoft.com\/support\/wp-json\/wp\/v2\/tags?post=3925"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}