-
How do I find what version
I am using?
From the ODBC Administrator (the same dialog that configures
your datasource), .select the "Drivers" tab. The driver is "HP3000
Data Access Driver". The version column lists the current
version as a four part number. Leading zeros in each part are
not significant.
Or on the host, logon:
:hello mgr.minisoft,mm
:setvar mstrace 7
:odbcsrvr
-
What are the parameters and options used to
start both the client and server portions of this product?
Click on the below link for a list of all the parameters and
options used to start both the client and server portions of
ODBC:
-
How do I use ManMan dates?
Click Here
Return to top
-
What causes the message
"REMOTE ABORTED THE CONNECTION" or "NET READ FAILED"?
Click Here
Return to top
-
How do I join more than
two datasets in Crystal Reports 6?
Seagate attempts to use a non-standard (SQL-92) syntax when
joining more than two tables. According to Seagate, the workaround
is to copy the P2SODBC.DLL file from version 5 and replace the
file with the same name in version 6.
For version 7, Seagate is using more than 10 different syntax
options for producing joins. The default, which uses the {oj
} syntax should work correctly.
Return to top
-
How do I use write access?
Currently we ship ODBC as Read access only. To enable Write
access edit MSJOB.MM.MINISOFT and change the line that looks
something like this:
!SETVAR MSSERVER000004 "30006 0 ODBCSRVR.MM.MINISOFT;PRI=DS;INFO='
S'"
To:
!SETVAR MSSERVER000004 "30006 0 ODBCSRVR.MM.MINISOFT;PRI=DS;INFO='
S W'"
Next, make sure you have MPE Write access to the database. Lastly
your DSN or Schema Editor file must specify an updateable access
mode (1-4) and the TurboImage password must be one that grants
write access. Image passwords are case-sensitive, unlike MPE
passwords.Return to top
-
How do I enable write access?
As shipped, the ODBCSRVR does not permit write access. To enable
this feature you must add the parameter ‘W’ to the ODBCSRVR
line in the MSJOB file.
Change:
!SETVAR MSSERVER000004 "30006 0 ODBCSRVR.MM.MINISOFT;PRI=DS;INFO='
S'"
To:
!SETVAR MSSERVER000004 "30006 0 ODBCSRVR.MM.MINISOFT;PRI=DS;INFO='
S W'"
Return to top
-
How do I configure the limit on size or time of a SELECT?
Add one or both of the following statements to your MSJOB file
(before the RUN command):
Maximum records per query set with:
!SETVAR MSQUERYRECLIMIT <records>
Maximum cpu time per query set with:
!SETVAR MSQUERYCPULIMIT <seconds>
Return to top
-
How do I use MSOffice, MSExcel, MSWord, MSQuery/97 and 2000?
The '97 version of these products operates differently than
'95. You must have a 'File Data Source' in order to use MSQuery.
If you have installed Service Pack 2 you can use either a System
or User DSN.
Please view the page on Creating
File DSNs.
Office 2000 allows you to choose either a System or User DSN.Return to top
-
How do I search on my TPI keys?
If upgrading to a version of ODBC/32 that supports TPI (1.1.0.6
or later) from an earlier version (1.1.0.5 or earlier), you
must re-create the links to your datasets. This step is required
to pass the key information to the client application where
it is stored.
Please
view the page on using TPI Keys.Return to top
-
How do I run more than one version of ODBCSRVR?
You can start more than one version of the ODBCSRVR program
at the same time by specifying both on the same MSSERVER000004
line.
Change the line:
!SETVAR MSSERVER000004 &
! "30006 0 ODBCSRVR.MM.MINISOFT S"
to:
!SETVAR MSSERVER000004 &
! "30006 0 ODBCSRVR.MM.MINISOFT S"+&
! "|31006 0 ODBCNEW.MM.MINISOFT S"
Port number 30006 in the DSN will start ODBCSRVR. Port number
31006 in the DSN will start ODBCNEW.
Do not add spaces before or after the pipe (|) character.
Alternatively, you can use an indirect file. Each line
of the file would contain the specification for connection.
MSJOB would contain the following line:
!SETVAR MSSERVER000004 "^ODBC0001"
The file ODBC0001 can contain the following lines:
30006 0 ODBCSRVR.MM.MINISOFT;PRI=DS;INFO=" S"
31006 0 ODBC2188.MM.MINISOFT;PRI=DS;INFO=" S"Return to top
-
How do I Insert/Update large amounts of data?
By default the driver is set to Item Level Locking. Trying to
do a mass Insert/Update of a Detail dataset will usually cause
an error because the Image Lock Descriptor Buffer is filled
up. This is an Image limitation. To get around this problem
you need to use Set Level Locking.
1. Edit your DSN and click on the Options tab.
2. Uncheck the "Enable item-level locking" box then save your
DSN. This will force Set Level Locking.
If you are trying to Insert more than 1,500 or so records you
may get an error. The normal cause of this is the HP3000 transaction
log was filled up. To correct this problem you need to
disable the HP3000 transactions.
1. Edit your DSN and click on the Options tab.
2. Check the "Disable HP3000 transactions" box then save your
DSN.Return to top
-
How do I run a server outside the MSJOB?
How can I run a single instance of my host software with tracing
turned on so I don’t impact my production users?
Log on as an MPE user with WS92. Run a command file such as:
SETVAR MSTEMPFM 1
SETVAR MSSERVER000004 "11006 0 ODBC2153.EXE.MINISOFT S W"
SETVAR MSTRACE 7
RUN MSSERVER.MM.MINISOFT;INFO="11000 SERVER.MSTRACE.MINISOFT"
Modify your DSN to use the same TCP port 11006 and run your
client application.Return to top
-
How are fields initialized when not included in an INSERT statement?
If you do not specifically include a field, the fields are initialized
as follows:
· Numeric fields are set
to zero.
· Character fields (X, U)
are filled with spaces.
· SQL_DATE fields are set
to 1900-01-01.Return to top
-
How do I explicitly join two or more tables?
To explicitly join two or more tables you must use the {oj }
syntax in the FROM clause. An example of an inner join is as
follows:
select td.problem_id,
td.company,
td.tech_code,
tm.name_last
from {oj track_detail td inner join techs_m tm on
td.tech_code = tm.tech_code}
where td.problem_id = 1001
Next is an example of an outer join. We only support
Left Outer Joins:
select td.problem_id,
td.company,
td.master_id,
md.master_desc
from {oj track_detail td left outer join master_detail
md on td.master_id = md.master_id}
where td.problem_id = 1001
You can combine inner and outer joins along with referencing
the same table multiple times. The example below opens the table
techs_m twice. Also notice you need parentheses to separate
each join condition:
select td.problem_id,
td.company,
pm.product_desc,
td.tech_code,
tm.name_last,
td.master_id,
{fn rtrim(md.master_desc)},
md.tech_code,
tm1.name_last
from {oj (((track_detail td inner join products_m
pm on td.product_code = pm.product_code)
inner join techs_m tm
on td.tech_code = tm.tech_code)
left outer join master_detail md on td.master_id
= md.master_id)
left outer join techs_m tm1
on md.tech_code = tm1.tech_code}
where td.tech_code = 'MARK'
Return to top
-
How do I do inner joins with Crystal Reports 9?
The default SQL syntax generated by Crystal Reports no longer
uses the {order to restore this functionality a registry entry
needs to be made.
1. Open Notepad then copy and paste the following four lines.
Windows Registry Editor Version 5.00
[HKEY_CURRENT_USER\Software\Crystal Decisions\9.0\Crystal Reports\Database\QueryBuilder\JoinBuilder]
OJSyntax
"OracleJoinBuilder2"="3kodbc"
2. Save the file as Joinbuilder.reg.
3. In Windows Explorer double-click Joinbuilder.reg.
You will be asked if you want to add this information to your
registry. Click on 'Yes'.
Crystal Reports 9 will now work the same as previous versions.
Return to top
-
How do I shut down MSJOB?
While you can just use OB, a more graceful way to bring it down
is to run the following program.
Stops MSJOB regardless of any user processes
:RUN MSJOBCMD.MM.MINISOFT;PARM = 2
Stops MSJOB if there are no user processes
:RUN MSJOBCMD.MM.MINISOFT;PARM=1
Displays the listeners that are running and user processes
associated with those listeners.
RUN MSJOBCMD.MM.MINISOFT
Return to top
-
How can dates be returned from SQL select calls?
Image supports only one data format (implicit). The K8 data type
should only used for dates. You must provide details for other than
the default conversion of other dates. The Minisoft ODBC and JDBC
drivers convert data types from Image to SQL using a set of default
maps. These defaults can be replaced by user defined conversions
using the Schema Editor utility. This utility can be found in the
Administrative tools installation for Minisoft ODBC and JDBC products.
Documentation can be found at http//www.minisoft.com/pages/middleware/odbc32/pages/schema_editor.htm
The Schema Editor can provide more than simple data conversion.
You can redefine any section of the record buffer into other data
types. For example some Image applications use an X100 to store
a series of numbers. In addition, you can define the scale factor
if your data is stored in whole number fractions (such as storing
currency in an I4 as cents with scale factor of 2).
Return to top
-
Why do I get a logon error for Security/3000 when I am not using
it?
For all Security/3000 related problems, please review the $STDLIST
of the MSJOB. The complete text of the VESOFT provided error message
will be printed following the prefix (VECHECKLOGON failed with).
Return to top
-
Why do I get a logon error for Security/3000
when I use the correct password?
When you see the error message: VECHECKLOGON failed with : ERROR:
lockfile open failed. The problem is that the HELLO PE trap is not
enabled. According to VESOFT you must enable the HELLO PE trap with
the following command:
%BACKG STARTJOB
%BACKG START,HELLO
Read this for more information.
If you are NOT using VESOFT Security/3000, then the Security/3000
intrinsics should be removed. While they are present, we MUST assume
that the system manager wants us to use Security/3000. To
remove the intrinsics, if you are on support with VESOFT, contact
VESOFT.
If you follow one the two procedures below we do not know what
effect this will have on other VESOFT products on you system. You
do not need to follow both procedures.
- Rename the file 'HELLO.PE.VESOFT'.
- Remove the VECHECKLOGON intrinsic.
:HELLO MANAGER.SYS
:SEGMENTER
-SL SL.PUB.SYS
-PURGESL SEGMENT,VESOFT'PROC'P
-EXIT
Return to top
-
Why do I see the error message: Unable to
create server process.
You can view the full error message by running the ODBCSRVR.
Normal operation should produce the message: Failed to get socket.
If the problem results from insufficient capabilities, you should
add Multiple RINS (MR) capability to the MM group.
ALTGROUP MM;CAP=+MR
If the file is not of type NMPRG, you must replace the executable
with a new copy. Use only MS92 or NFT to upload the replacement
file.
Please contact your support for information on resolving other problems.Return to top
-
Why does I see an error while starting the
Schema Editor fail with a comment about OLEAUT32.DLL?
The
Schema
Editor may need updated 32-bit OLE files for some users of the
original Win95. WinNT and OSR2 users do not need these files. Updated
versions of these files are in use on most Win95 systems.Return to top
-
Why do I see #DELETED in every field when
I open a (MASTER) table?
Some Image numeric type values are treated as signed values.
If they are not signed and are key values, your results will not
be as expected.Return to top
-
Why can I open and see data in a (DETAIL)
table, but searches return no data?
You must create a database view using the
Schema
Editor to set the type of the value to signed (NO).Return to top
-
Why do I see the error message: [Minisoft][3kodbc.dll]
connect: Connection refused (#10061)?
Periodically the demonstration copies and some licensed
copies of the ODBC/32 driver expire. Please contact your Minisoft
sales representative about getting an extension.
The job MSJOB.MM.MINISOFT must be streamed prior to making
client connections.
The port number specified on the client must match the port
number in the MSJOB file for the ODBCSRVR process. As shipped,
this number is 30006.
The address given in the DSN is not that of the HP 3000
CPU. Most TELNET access to the HP e3000 is via an external box
(DTC) and is a separate address from the HP e3000.
A fire wall or proxy server is not allowing connections
on port 30006. Contact your network administrator or use an
allowed port.Return to top
-
Why do I get a non-existent permanent file
error message?
One of the following files does not exist or was not completely
qualified: SCHEMA, DATABASE, or any of the tables specified by the
SCHEMA. Remember that the SCHEMA referenced by the Data Source Name
(DSN) refers to a files created by the
Schema
Editor application and not the Image Schema file. Check that
ALL the tables in your schema exist and are accessible.Return to top
-
Why is the list of available tables empty
(or incomplete)?
The TurboImage password is incorrect. This password is case-sensitive
and must be entered carefully. There can be several passwords that
allow access to more or fewer of the datasets and fields.
If you are unaware of the password, these
instructions.Return to top
-
Why do I see the error message: ODBCSRVR
is not enabled for write access?
MSJOB has not been modified for write access
and you are trying to open a database with Mode 1,2,3, or 4 or are
trying to open a KSAM or MPE file for write access. You need to
either change MSJOB to allow write access or
change the open Mode for your database, KSAM or MPE files.Return to top
-
Why does the message Overlapped I/O operation
is in progress appear?
Complete message:
"[MiniSoft] [3kodbc.dll] In (NetConnect), error 997 Overlapped
I/O operation is in progress. - Connect() Cannot connect to (192.168.23.7022644)"
This message will occur if a connection cannot be made to the
ODBC Server process. Common causes are
1. MSJOB is not running.
2. The product is not currently licensed (Evaluation expired)
3. Incorrect port number
4. Incorrect host name or address
5. The port is blocked by a firewallReturn to top
-
SQL Date Format
The escape sequence for date, time, and timestamp literals is:
{literal-type 'value'}
where literal-type is one of the following options: